MBR technology is known for efficiently separating solids from wastewater using membranes. However, membrane permeability, or the rate at which water passes through the membrane, can vary and impact system performance. Let’s explore the key factors that influence MBR membrane permeability.

  1. Membrane Fouling

Membrane fouling is a primary factor affecting permeability. Fouling occurs when particles, microorganisms, or other substances accumulate on the membrane surface or within its pores. This accumulation reduces the available pathways for water to pass through, decreasing permeability. Effective fouling control strategies, such as regular cleaning and maintenance, are essential to maintain optimal permeability.

  1. Transmembrane Pressure

Transmembrane pressure (TMP) is the pressure difference across the membrane and plays a significant role in permeability. High TMP can lead to membrane compaction and a reduction in pore size, limiting water flow. Monitoring and controlling TMP within an acceptable range are critical to preserving membrane permeability.

  1. Membrane Material and Pore Size

The choice of membrane material and its pore size is another crucial factor. Different membrane materials have varying permeability characteristics. Additionally, the size of the pores can impact the types of particles and substances that can pass through. Selecting the right membrane material and pore size for the specific application is essential for achieving the desired permeability and separation efficiency.

SPERTA MBR Membrane Expo VIII
SPERTA MBR Membrane Module

In conclusion, several factors can affect MBR membrane permeability, including membrane fouling, transmembrane pressure, and membrane material characteristics. Managing these factors effectively is essential to ensure consistent and efficient wastewater treatment in MBR systems. Proper maintenance, monitoring, and membrane selection are key strategies for maintaining optimal permeability and system performance.

While several factors can influence MBR membrane permeability, the choice of membrane supplier can also significantly impact. In this section, we’ll explore the advantages of SPERTA Membrane and how it can contribute to maintaining and enhancing membrane permeability in MBR systems.

SPERTA MBR Membrane IV
SPERTA MBR Membrane

Why Choose SPERTA MBR Membrane?

Enhanced Fouling Resistance: SPERTA Membrane is engineered with advanced fouling-resistant properties. Its surface characteristics and design minimize the adhesion of particles and microorganisms, reducing the risk of fouling. This enhanced fouling resistance translates to longer-lasting, high-performance membranes with improved permeability.

High Permeability and Flux Rates: SPERTA Membrane is known for its high permeability and flux rates. Its precisely designed pores allow for efficient water flow, resulting in excellent permeability. This ensures consistent and reliable performance and contributes to lower energy consumption in MBR systems.

Tailored Solutions: One of the significant advantages of SPERTA Membrane is its ability to provide tailored membrane solutions. Whether you require membranes with specific pore sizes, materials, or configurations to address unique wastewater challenges, SPERTA Membrane can offer customized solutions to optimize permeability and overall MBR system efficiency.

SPERTA 500D MBR Membrane
SPERTA 500D MBR Membrane

Conclusion

Incorporating SPERTA Membrane into your MBR system can provide several advantages, including enhanced fouling resistance, high permeability, and tailored solutions. These benefits contribute to maintaining and improving membrane permeability, ensuring efficient and reliable wastewater treatment in MBR systems. When selecting membrane suppliers, considering the advantages offered by SPERTA Membrane can play a vital role in achieving optimal MBR performance.

Kevin Chen

Kevin Chen

Hi, I'm the author of this post and have been in this field for over 5 years. If you have questions regarding the MBR membrane products or want to purchase the MBR membrane, please feel free to contact me by email. kevin@spertasystems.com

Like this article?

Share on Facebook
Share on Twitter
Share on Linkdin
Share on Pinterest

More to explorer

How Much is the MBR Membrane?

How Much is the MBR Membrane?

The MBR membrane is widely used in various sewage treatments. Many people are wondering how much is the MBR membrane?

MBR Offline Cleaning I

How to Do Offline Chemical Cleaning For MBR Membranes

Step 1: Remove the suction tube and the aeration tube from the MBR module. Then take the MBR module out of the tank. 

Step 2: Use a nozzle to clean and remove the activated sludge attached to the surface of the fibers.

Step 3: Take the MBR elements out of the module and immerse the elements in a prescribed chemical solution tank. Stay for 6-12 hours.

Step 4: Take out the MBR element from the immersion cleaning tank and wash it thoroughly with water to remove the chemical solution.

Step 5: Install the MBR on the MBR module after cleaning.

Step 6: Connect the aeration pipe and put the module in the tank. Stop the filtration, just let the aeration run for more than 30 minutes, and then start the filtration.

Step 7: Before discharging the chemical solution, reduce the sodium hypochlorite with sodium thiosulfate (Na2S2O3 NH2O), and then discharge.

Step 8: If there is a large amount of inorganic scale on the surface of the MBR after sodium hypochlorite washing, acid washing is also needed.

How To Avoid MBR Membrane Fouling?

How To Avoid MBR Membrane Fouling?

The MBR membrane should be cleaned after operating for a period of time. Effective cleaning can prevent fouling caused by colloid, salt scaling, microorganisms, and other substances and can also eliminate the possibility of damage to the membrane elements caused by large particles.

What is Hydraulic Retention Time HRT

What is Hydraulic Retention Time (HRT) and How is it Calculated?

Hydraulic Retention Time (HRT) is a term used in water treatment processes, referring to the average time that wastewater remains in a reactor, essentially the average reaction time between the wastewater and the microorganisms in the biological reactor.

Need MBR Membrane for your plants?
Get The Latest Updates

Subscribe To Our Newsletter

No spam, notifications only about new article updates regarding MBR membrane Technologies.

Sperta System

Ask For A Quick Quote

We will contact you within 6 hours, please pay attention to the email with the suffix “@spertasystems.com”.