How To Backwash MBR Membranes?
Tip 1: Use produced water or higher quality water as the backwash water.
Tip 2: Control the backwash pressure at 50 – 100 kPa.
Tip 3: Set backwash flow: 2 times of the produced water.
Tip 4: Set backwash time: 1 – 5min.
Tip 5: Adjust the backwash process per 1-12h according to the produced water quality.